NEC Article 120 Load Calculations
Reference for load-calculation scope and planning boundaries before branch-circuit, feeder, or service sizing decisions are treated as field-ready.
NEC field reference index used with TradeHub electrical calculators for load review, conductor sizing, ampacity checks, raceway fill, grounding, receptacle rules, EV charging, and installation review.
Use this electrical resource index as the parent hub for NEC field references that support TradeHub electrical calculator workflows. The workflow map shows how the references connect; the grouped index below gives direct access to each resource page.
Purpose of These References
These resource pages help you understand the NEC rules, field conditions, or common sizing boundaries before using a calculation tool. Each reference explains the condition first, then points to the related TradeHub workflow when load, breaker, conductor, ampacity, voltage-drop, raceway, or box-fill math is the next step.
Electrical Workflow Map
Load Review
Article 120 • 220.82 • 125%
Breaker / OCPD
240.4(B) • 240.87
Wire Size
310.12 • 625
Ampacity
310.16 • 310.15 • 110.14(C)
Raceway Fill
Chapter 9 • 300.5
Field Checks
210 • 250 • 422 • 110
Reference Group
References used when a field load, breaker, service, feeder, or EV branch-circuit decision needs a code-source checkpoint before calculator results are trusted.
Reference for load-calculation scope and planning boundaries before branch-circuit, feeder, or service sizing decisions are treated as field-ready.
Residential optional-method reference used when dwelling load inputs, demand factors, and service or feeder sizing need a clear NEC 220.82 review.
Field reference for separating continuous-load sizing from equipment ratings, conductor ampacity, EV charging, and breaker review.
Reference for when the next standard overcurrent device rule may apply and when conductor ampacity or small-conductor limits block it.
Field reference for small-conductor overcurrent protection limits before a breaker or fuse size is trusted from table ampacity alone.
Motor branch-circuit short-circuit and ground-fault protection reference for FLC, protective-device multipliers, and overload separation.
Dwelling service and feeder conductor reference for 310.12 screening before service-rating, terminal, and derating checks are finalized.
EVSE branch-circuit reference for continuous-load sizing, breaker patterns, conductor selection, and field handoffs.
EV load-management reference for EVSE output limits, energy management systems, continuous-load treatment, and service-load boundaries.
Reference Group
References used before conductor ampacity, adjustment, correction, terminal-temperature, and cable-assembly limits are treated as field-ready.
Field lookup for base conductor ampacity before adjustment, correction, and terminal-temperature review.
Reference for ambient correction, current-carrying conductor adjustment, rooftop heat, and neutral-count conditions.
Current-carrying conductor adjustment reference for conductor count ranges, neutral-count boundaries, and short-raceway handoffs.
Ambient temperature correction reference for conductor insulation columns, correction factors, and terminal-temperature boundaries.
Terminal-temperature reference for checking whether 60°C, 75°C, or equipment labeling limits control the final conductor decision.
NM cable ampacity reference for 90°C adjustment math, final 60°C limits, bundling, insulation contact, and field-use boundaries.
Reference Group
References used when equipment grounding conductors or grounding electrode conductors need to stay separate from load, ampacity, and voltage-drop decisions.
Reference for equipment grounding conductor sizing from the overcurrent device and for voltage-drop upsizing handoffs.
Field reference for current-cycle EGC box-fill allowances, isolated grounding conductors, and legacy method boundaries.
Grounding electrode conductor reference for service grounding electrode connections, service conductor basis, and sizing boundaries.
Reference Group
References used when raceway fill, short nipples, box fill, pull-box sizing, cover depth, and physical conductor protection affect whether a circuit can move forward.
Field reference for raceway fill, conductor area, compact aluminum, bare grounding conductors, and conduit table handoffs.
Short raceway nipple reference for the 24-inch Chapter 9 allowance, 60 percent fill boundary, and separate ampacity checks.
Box-fill reference for conductor volume allowances, device yokes, grounding conductors, clamps, and available box capacity.
Field reference for straight pulls, angle pulls, U pulls, splices, and the #4 AWG or larger pull-box sizing boundary.
Physical protection reference for bored holes, framing clearance, nail plates, raceway entries, fittings, and damage exposure.
NEC 300.5 minimum cover reference for wiring method, Table 300.5 cover review, wet-location conductors, vehicle areas, and emerging-from-grade protection.
Reference Group
References used when required circuits, receptacle locations, GFCI, AFCI, and equipment receptacle rules need a separate field checkpoint.
GFCI protection reference for dwelling and field-location checks before receptacle results are treated as complete.
AFCI protection reference for dwelling branch-circuit areas, protection methods, and circuit-planning boundaries.
Receptacle outlet reference for dwelling spacing, required locations, and separation from load or breaker sizing decisions.
HVAC service receptacle reference for equipment-location checks and separation from the equipment branch circuit.
Garage branch-circuit reference for dwelling garage receptacles, detached-garage review, GFCI checks, and EV charging boundaries.
Reference Group
References used when equipment access, field markings, arc-energy reduction, and disconnecting means affect the final field review.
Listed-equipment reference for manufacturer instructions, markings, breaker compatibility, terminal limits, torque values, and nameplate checks.
Arc-flash marking reference for service equipment and field safety labeling boundaries.
Field-applied hazard marking reference for durable labels, wording, visibility, and equipment warning boundaries.
Working clearance reference for electrical equipment access, depth, width, height, and dedicated-space review.
HVAC disconnect location reference for within-sight placement, ready access, working-space review, and equipment-boundary checks.
Arc-energy reduction reference for large circuit breakers and equipment-level protection review.
Appliance disconnecting-means reference for fixed appliances, cord-and-plug disconnects, lockable breakers, and unit switches.
Source Scope
These pages are field reference summaries used to support TradeHub calculator workflows. They do not replace the adopted NEC, local amendments, manufacturer instructions, plan review, utility requirements, or AHJ interpretation. Review the TradeHub Code Citation & Source Log for source alignment records and the TradeHub Methodology page for how field references are scoped.
Reference Area In Review
This TradeHub reference area is not live yet. Planned review timing: .